Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.079
Filtrar
1.
PLoS One ; 19(5): e0303090, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38722902

RESUMEN

This study aimed to determine whether filtering out walking-related actigraphy data improves the reliability and accuracy of real-world upper extremity activity assessment in children with unilateral cerebral palsy. Twenty-two children aged 4-12 years diagnosed with unilateral cerebral palsy were included in this study, which was drawn from a two-phase randomized controlled trial conducted from July 2021 to December 2022. Data were collected from a tertiary hospital in Seoul, Republic of Korea. Participants were monitored using tri-axial accelerometers on both wrists across three time points (namely, T0, T1, and T2) over 3 days; interventions were used between each time point. Concurrently, an in-laboratory study focusing on walking and bimanual tasks was conducted with four participants. Data filtration resulted in a reduction of 8.20% in total data entry. With respect to reliability assessment, the intra-class correlation coefficients indicated enhanced consistency after filtration, with increased values for both the affected and less-affected sides. Before filtration, the magnitude counts for both sides showed varying tendencies, depending on the time points; however, they presented a consistent and stable trend after filtration. The findings of this research underscore the importance of accurately interpreting actigraphy measurements in children with unilateral cerebral palsy for targeted upper limb intervention by filtering walking-induced data.


Asunto(s)
Actigrafía , Parálisis Cerebral , Caminata , Humanos , Parálisis Cerebral/fisiopatología , Actigrafía/métodos , Niño , Caminata/fisiología , Masculino , Femenino , Preescolar , Reproducibilidad de los Resultados , República de Corea
2.
Int J Behav Nutr Phys Act ; 21(1): 48, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38671485

RESUMEN

BACKGROUND: Sedentary behavior (SB) is a recognized risk factor for many chronic diseases. ActiGraph and activPAL are two commonly used wearable accelerometers in SB research. The former measures body movement and the latter measures body posture. The goal of the current study is to quantify the pattern and variation of movement (by ActiGraph activity counts) during activPAL-identified sitting events, and examine associations between patterns and health-related outcomes, such as systolic and diastolic blood pressure (SBP and DBP). METHODS: The current study included 314 overweight postmenopausal women, who were instructed to wear an activPAL (at thigh) and ActiGraph (at waist) simultaneously for 24 hours a day for a week under free-living conditions. ActiGraph and activPAL data were processed to obtain minute-level time-series outputs. Multilevel functional principal component analysis (MFPCA) was applied to minute-level ActiGraph activity counts within activPAL-identified sitting bouts to investigate variation in movement while sitting across subjects and days. The multilevel approach accounted for the nesting of days within subjects. RESULTS: At least 90% of the overall variation of activity counts was explained by two subject-level principal components (PC) and six day-level PCs, hence dramatically reducing the dimensions from the original minute-level scale. The first subject-level PC captured patterns of fluctuation in movement during sitting, whereas the second subject-level PC delineated variation in movement during different lengths of sitting bouts: shorter (< 30 minutes), medium (30 -39 minutes) or longer (> 39 minute). The first subject-level PC scores showed positive association with DBP (standardized ß ^ : 2.041, standard error: 0.607, adjusted p = 0.007), which implied that lower activity counts (during sitting) were associated with higher DBP. CONCLUSION: In this work we implemented MFPCA to identify variation in movement patterns during sitting bouts, and showed that these patterns were associated with cardiovascular health. Unlike existing methods, MFPCA does not require pre-specified cut-points to define activity intensity, and thus offers a novel powerful statistical tool to elucidate variation in SB patterns and health. TRIAL REGISTRATION: ClinicalTrials.gov NCT03473145; Registered 22 March 2018; https://clinicaltrials.gov/ct2/show/NCT03473145 ; International Registered Report Identifier (IRRID): DERR1-10.2196/28684.


Asunto(s)
Análisis de Componente Principal , Conducta Sedentaria , Sedestación , Dispositivos Electrónicos Vestibles , Humanos , Femenino , Persona de Mediana Edad , Acelerometría/instrumentación , Acelerometría/métodos , Presión Sanguínea/fisiología , Actigrafía/instrumentación , Actigrafía/métodos , Anciano , Sobrepeso , Posmenopausia/fisiología , Ejercicio Físico/fisiología , Movimiento
3.
BMC Pediatr ; 24(1): 273, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38664706

RESUMEN

BACKGROUND: Accurate assessment of physical activity and motor function in children with cerebral palsy is crucial for determining the effectiveness of interventions. This study aimed to investigate the correlation between real-world activity monitoring outcomes and in-laboratory standardized hand function assessments in children with unilateral cerebral palsy. METHODS: Actigraphy data were collected over 3 days from children aged 4-12 years with unilateral cerebral palsy before in-laboratory assessments. To tackle the high dimensionality and collinearity of actigraphy variables, we first applied hierarchical clustering using the Pearson correlation coefficient as the distance metric and then performed a principal component analysis (PCA) to reduce the dimensionality of our data. RESULTS: Both hierarchical clustering and PCAs revealed a consistent pattern in which magnitude ratio variables (ln[affected side magnitude/less-affected side magnitude]) were more strongly associated with standardized assessments of hand function than with activity time and distance domain variables. Hierarchical clustering analysis identified two distinct clusters of actigraphy variables, with the second cluster primarily consisting of magnitude ratio variables that exhibited the strongest correlation with Melbourne Assessment 2, Pediatric Motor Activity Log, Assisting Hand Assessment, and Manual Ability Classification System level. Principal component 2, primarily representing the magnitude ratio domain, was positively associated with a meaningful portion of subcategories of standardized measures, whereas principal component 1, representing the activity time and distance component, showed limited associations. CONCLUSIONS: The magnitude ratio of actigraphy can provide additional objective information that complements in-laboratory hand function assessment outcomes in future studies of children with unilateral cerebral palsy. TRIAL REGISTRATION IN CLINICALTRIALS.GOV: NCT04904796 (registered prospectively; date of registration: 23/05/2021).


Asunto(s)
Actigrafía , Parálisis Cerebral , Mano , Humanos , Parálisis Cerebral/fisiopatología , Niño , Actigrafía/métodos , Femenino , Masculino , Preescolar , Mano/fisiopatología , Análisis de Componente Principal , Análisis por Conglomerados
4.
Medicina (Kaunas) ; 60(4)2024 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-38674278

RESUMEN

Background: Insomnia is increasingly recognized for its marked impact on public health and is often associated with various adverse health outcomes, including cardiovascular diseases and mental health disorders. The aim of this study was to investigate the efficacy of pre-sleep dim light therapy (LT) as a non-pharmacological intervention for insomnia in adults, assessing its influence on sleep parameters and circadian rhythms. Methods: A randomized, open-label, two-arm clinical trial was conducted over two weeks with 40 participants aged 20-60 years, all of whom had sleep disorders (CRIS, KCT0008501). They were allocated into control and LT groups. The LT group received exposure to warm-colored light, minimizing the blue spectrum, before bedtime. The study combined subjective evaluation via validated, sleep-related questionnaires, objective sleep assessments via actigraphy, and molecular analyses of circadian clock gene expression in peripheral blood mononuclear cells. Baseline characteristics between the two groups were compared using an independent t-test for continuous variables and the chi-squared test for categorical variables. Within-group differences were assessed using the paired t-test. Changes between groups were analyzed using linear regression, adjusting for each baseline value and body mass index. The patterns of changes in sleep parameters were calculated using a linear mixed model. Results: The LT group exhibited significant improvements in sleep quality (difference in difference [95% CI]; -2.00 [-3.58, -0.43], and sleep efficiency (LT: 84.98 vs. control: 82.11, p = 0.032), and an advanced Dim Light Melatonin Onset compared to the control group (approximately 30 min). Molecular analysis indicated a significant reduction in CRY1 gene expression after LT, suggesting an influence on circadian signals for sleep regulation. Conclusions: This study provides evidence for the efficacy of LT in improving sleep quality and circadian rhythm alignment in adults with insomnia. Despite limitations, such as a small sample size and short study duration, the results underscore the potential of LT as a viable non-pharmacological approach for insomnia. Future research should expand on these results with larger and more diverse cohorts followed over a longer period to validate and further elucidate the value of LT in sleep medicine. Trial registration: The trial was registered with the Clinical Research Information Service (KCT0008501).


Asunto(s)
Fototerapia , Trastornos del Inicio y del Mantenimiento del Sueño , Humanos , Trastornos del Inicio y del Mantenimiento del Sueño/terapia , Adulto , Proyectos Piloto , Masculino , Femenino , Persona de Mediana Edad , Fototerapia/métodos , Estudios de Factibilidad , Resultado del Tratamiento , Actigrafía/métodos , Encuestas y Cuestionarios , Sueño/fisiología , Ritmo Circadiano/fisiología
6.
Alzheimers Dement ; 20(5): 3211-3218, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38497216

RESUMEN

BACKGROUND: Wrist-worn actigraphy can be an objective tool to assess sleep and other behavioral and psychological symptoms in dementia (BPSD). We investigated the feasibility of using wearable actigraphy in agitated late-stage dementia patients. METHODS: Agitated, late-stage Alzheimer's dementia care home residents in Greater London area (n = 29; 14 females, mean age ± SD: 80.8 ± 8.2; 93.1% White) were recruited to wear an actigraphy watch for 4 weeks. Wearing time was extracted to evaluate compliance, and factors influencing compliance were explored. RESULTS: A high watch-acceptance (96.6%) and compliance rate (88.0%) was noted. Non-compliance was not associated with age or BPSD symptomatology. However, participants with "better" cognitive function (R = 0.42, p = 0.022) and during nightshift (F1.240, 33.475 = 8.075, p = 0.005) were less compliant. Female participants were also marginally less compliant (F1, 26 = 3.790, p = 0.062). DISCUSSIONS: Wrist-worn actigraphy appears acceptable and feasible in late-stage agitated dementia patients. Accommodating the needs of both the patients and their carers may further improve compliance.


Asunto(s)
Actigrafía , Demencia , Estudios de Factibilidad , Muñeca , Humanos , Femenino , Actigrafía/métodos , Actigrafía/instrumentación , Masculino , Anciano de 80 o más Años , Demencia/diagnóstico , Agitación Psicomotora/diagnóstico , Anciano , Dispositivos Electrónicos Vestibles , Cooperación del Paciente , Londres , Sueño/fisiología
7.
Sleep Med ; 116: 138-146, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38460419

RESUMEN

OBJECTIVES: Physical activity (PA) is recommended as part of the management of narcolepsy type 1 (NT1). This study aimed at 1) characterizing PA in children and adolescents treated for NT1 using objective and subjective measurements, 2) evaluating how PA is associated with NT1 symptoms and comorbidities, and 3) evaluating the effects of an Adapted Physical Activity (APA) program on PA and clinical characteristics. PATIENTS/METHODS: Patients with NT1 from the National Reference Center of Narcolepsy (Lyon, France) were consecutively included in an APA intervention protocol. Narcolepsy symptoms and comorbidities were collected using standardized questionnaires and sustained attention was evaluated using the Bron-Lyon Attention Stability Test before and after the four-week APA intervention. PA was measured objectively using actigraphy throughout the study. RESULTS: Twenty-seven NT1 patients were included (median age 14.7 years [8.3-18.4], cataplexy 88.9%, obesity 37.0%). At baseline, 52.4% of the patients had satisfactory PA levels according to international recommendations. Patients with leisure-time PA (LTPA) showed higher quality of life than patients without. 45% of the patients increased PA during the intervention compared to baseline. These responsive patients had more depressive feelings and tended to have lower objective PA than non-responsive patients at baseline. No significant correlation was found between PA levels before and during the intervention and other clinical data. CONCLUSIONS: Most children with NT1 showed satisfying PA levels despite their daytime sleepiness. LTPA engagement was associated with higher quality of life. An APA intervention could be effective in children with narcolepsy, especially for those with depressive feelings.


Asunto(s)
Narcolepsia , Calidad de Vida , Niño , Adolescente , Humanos , Narcolepsia/diagnóstico , Actigrafía/métodos , Obesidad/complicaciones , Ejercicio Físico
8.
Sleep ; 47(5)2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38381532

RESUMEN

STUDY OBJECTIVES: To compare sleep and 24-hour rest/activity rhythms (RARs) between cognitively normal older adults who are ß-amyloid-positive (Aß+) or Aß- and replicate a novel time-of-day-specific difference between these groups identified in a previous exploratory study. METHODS: We studied 82 cognitively normal participants from the Baltimore Longitudinal Study of Aging (aged 75.7 ±â€…8.5 years, 55% female, 76% white) with wrist actigraphy data and Aß+ versus Aß- status measured by [11C] Pittsburgh compound B positron emission tomography. RARs were calculated using epoch-level activity count data from actigraphy. We used novel, data-driven function-on-scalar regression analyses and standard RAR metrics to cross-sectionally compare RARs between 25 Aß+ and 57 Aß- participants. RESULTS: Compared to Aß- participants, Aß+ participants had higher mean activity from 1:00 p.m. to 3:30 p.m. when using less conservative pointwise confidence intervals (CIs) and from 1:30 p.m. to 2:30 p.m. using more conservative, simultaneous CIs. Furthermore, Aß+ participants had higher day-to-day variability in activity from 9:00 a.m. to 11:30 a.m. and lower variability from 1:30 p.m. to 4:00 p.m. and 7:30 p.m. to 10:30 p.m. according to pointwise CIs, and lower variability from 8:30 p.m. to 10:00 p.m. using simultaneous CIs. There were no Aß-related differences in standard sleep or RAR metrics. CONCLUSIONS: Findings suggest Aß+ older adults have higher, more stable day-to-day afternoon/evening activity than Aß- older adults, potentially reflecting circadian dysfunction. Studies are needed to replicate our findings and determine whether these or other time-of-day-specific RAR features have utility as markers of preclinical Aß deposition and if they predict clinical dementia and agitation in the afternoon/evening (i.e. "sundowning").


Asunto(s)
Actigrafía , Péptidos beta-Amiloides , Tomografía de Emisión de Positrones , Humanos , Femenino , Masculino , Anciano , Péptidos beta-Amiloides/metabolismo , Actigrafía/estadística & datos numéricos , Actigrafía/métodos , Tomografía de Emisión de Positrones/métodos , Anciano de 80 o más Años , Estudios Longitudinales , Descanso/fisiología , Compuestos de Anilina , Sueño/fisiología , Biomarcadores/metabolismo , Biomarcadores/análisis , Ritmo Circadiano/fisiología , Tiazoles , Estudios Transversales , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo
9.
Sleep Med ; 115: 21-29, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38325157

RESUMEN

STUDY OBJECTIVE: To provide a comprehensive assessment of sleep state misperception in insomnia disorder (INS) and good sleepers (GS) by comparing recordings performed for one night in-lab (PSG and night review) and during several nights at-home (actigraphy and sleep diaries). METHODS: Fifty-seven INS and 29 GS wore an actigraphy device and filled a sleep diary for two weeks at-home. They subsequently completed a PSG recording and filled a night review in-lab. Sleep perception index (subjective/objective × 100) of sleep onset latency (SOL), sleep duration (TST) and wake duration (TST) were computed and compared between methods and groups. RESULTS: GS displayed a tendency to overestimate TST and WASO but correctly perceived SOL. The degree of misperception was similar across methods within the GS group. In contrast, INS underestimated their TST and overestimated their SOL both in-lab and at-home, yet the severity of misperception of SOL was larger at-home than in-lab. Finally, INS overestimated WASO only in-lab while correctly perceiving it at-home. While only the degree of TST misperception was stable across methods in INS, misperception of SOL and WASO were dependent on the method used. CONCLUSIONS: We found that GS and INS exhibit opposite patterns and severity of sleep misperception. While the degree of misperception in GS was similar across methods, only sleep duration misperception was reliably detected by both in-lab and at-home methods in INS. Our results highlight that, when assessing sleep misperception in insomnia disorder, the environment and method of data collection should be carefully considered.


Asunto(s)
Actigrafía , Trastornos del Inicio y del Mantenimiento del Sueño , Humanos , Polisomnografía/métodos , Actigrafía/métodos , Trastornos del Inicio y del Mantenimiento del Sueño/diagnóstico , Sueño , Latencia del Sueño
10.
J Sports Sci ; 42(1): 9-16, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38394032

RESUMEN

The influence of the ActiGraph® processing criteria on estimating step counts in chronic obstructive pulmonary disease (COPD) remains uncertain. This study aimed to assess the influence of filters, epoch lengths and non-wearing time (NWT) algorithms on steps/day in people with COPD. ActiGraph GT3X+ was worn on the waist for seven days. Steps were detected using different filters (normal and low-frequency extension [LFE]), epoch lengths (15s and 60s), and NWT algorithms (Choi and Troiano). Linear mixed-effects model was applied to assess the effects of filter, epoch length, NWT algorithm on steps/day. Lin's concordance correlation and Bland-Altman were used to measure agreement. A total of 136 people with COPD (107 male; 69 ± 8 years; FEV1 51 ± 17% predicted) were included. Significant differences were found between filters (p < 0.001), but not between epoch lengths or NWT algorithms. The LFE increased, on average, approximately 7500 steps/day compared to the normal filter (p < 0.001). Agreement was poor (<0.3) and proportional bias was significant when comparing steps/day computed with different filters, regardless of the epoch length and NWT algorithm. Filter choice but not epoch lengths or NWT algorithms seem to impact measurement of steps/day. Future studies are needed to recommend the most accurate technique for measuring steps/day in people with COPD.


Asunto(s)
Actigrafía , Enfermedad Pulmonar Obstructiva Crónica , Humanos , Masculino , Actigrafía/métodos , Acelerometría/métodos , Tiempo , Algoritmos
11.
BMC Palliat Care ; 23(1): 52, 2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38395866

RESUMEN

BACKGROUND: Actigraphy offers a promising way to objectively assess pediatric sleep. Aim of the study was investigating the extent to which actigraphy used in children and adolescents with life-limiting conditions is consistent with two other measures of sleep diagnostics. METHODS: In this monocentric prospective study N = 26 children and adolescents with life-limiting conditions treated on a pediatric palliative care unit were assessed. For three consecutive nights they wore an actigraph; the 24-hours sleep protocol documented by nurses and the Sleep Screening for Children and Adolescents with Complex Chronic Conditions (SCAC) answered by parents were analyzed. Patient characteristics and the parameters sleep onset, sleep offset, wake after sleep onset (WASO), number of wake phases, total sleep time (TST) and sleep efficiency (SE) were descriptively examined. Percentage bend correlations evaluated the three measures' concordance. RESULTS: Descriptively, and except for the number of waking episodes, the different measures' estimations were comparable. Significant correlations existed between actigraphy and the sleep protocol for sleep onset (r = 0.83, p = < 0.001) and sleep offset (r = 0.89, p = < 0.001), between actigraphy and SCAC for SE (r = 0.59, p = 0.02). CONCLUSION: Agreement of actigraphy with the focused sleep measures seems to be basically given but to varying degrees depending on the considered parameters.


Asunto(s)
Actigrafía , Cuidadores , Humanos , Adolescente , Niño , Actigrafía/métodos , Estudios Prospectivos , Juicio , Sueño , Padres , Encuestas y Cuestionarios
12.
Psychiatry Res ; 332: 115693, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38194801

RESUMEN

Major Depressive Disorder (MDD) is a heterogeneous disorder, resulting in challenges with early detection. However, changes in sleep and movement patterns may help improve detection. Thus, this study aimed to explore the utility of wrist-worn actigraphy data in combination with machine learning (ML) and deep learning techniques to detect MDD using a commonly used screening method: Patient Health Questionnaire-9 (PHQ-9). Participants (N = 8,378; MDD Screening = 766 participants) completed the and wore Actigraph GT3X+ for one week as part of the National Health and Nutrition Examination Survey (NHANES). Leveraging minute-level, actigraphy data, we evaluated the efficacy of two commonly used ML approaches and identified actigraphy-derived biomarkers indicative of MDD. We employed two ML modeling strategies: (1) a traditional ML approach with theory-driven feature derivation, and (2) a deep learning Convolutional Neural Network (CNN) approach, coupled with gramian angular field transformation. Findings revealed movement-related features to be the most influential in the traditional ML approach and nighttime movement to be the most influential in the CNN approach for detecting MDD. Using a large, nationally-representative sample, this study highlights the potential of using passively-collected, actigraphy data for understanding MDD to better improve diagnosing and treating MDD.


Asunto(s)
Trastorno Depresivo Mayor , Dispositivos Electrónicos Vestibles , Humanos , Trastorno Depresivo Mayor/diagnóstico , Encuestas Nutricionales , Sueño , Actigrafía/métodos
13.
BMC Public Health ; 24(1): 87, 2024 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-38178012

RESUMEN

BACKGROUND AND OBJECTIVES: Older adults keep transforming with Baby Boomers and Gen Xers being the leading older population. Their lifestyle, however, is not well understood. The middle-aged and older Chinese adults' health using actigraphy in Taiwan (MOCHA-T) collected both objective and subjective data to depict the health and lifestyle of this population. The objectives, design, and measures of the MOCHA-T study are introduced, and the caveats and future directions related to the use of the data are presented. METHODS: People aged 50 and over were recruited from the community, with a subset of women aged 45-49 invited to supplement data on menopause and aging. Four instruments (i.e., self-reported questionnaires, diary, wrist actigraphy recorder, and GPS) were used to collect measures of sociodemographic, health, psychosocial, behavioral, temporal, and spatial data. RESULTS: A total of 242 participants who returned the informed consent and questionnaires were recruited in the MOCHA-T study. Among them, 94.6%, 95.0%, and 25.2% also completed the diary, actigraphy, and GPS data, respectively. There was almost no difference in sociodemographic characteristics between those with and without a completed diary, actigraphy, and GPS data, except for age group and educational level for those who returned completed actigraphy data. CONCLUSION: The MOCHA-T study is a multidimensional dataset that allows researchers to describe the health, behaviors, and lifestyle patterns, and their interactions with the environment of the newer generation of middle-aged and older adults in Taiwan. It can be compared with other countries with actigraphy and GPS-based lifestyle data of middle-aged and older adults in the future.


Asunto(s)
Actigrafía , Sueño , Persona de Mediana Edad , Humanos , Femenino , Anciano , Actigrafía/métodos , Taiwán , Estilo de Vida , China
14.
Sensors (Basel) ; 24(2)2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-38276327

RESUMEN

The development of consumer sleep-tracking technologies has outpaced the scientific evaluation of their accuracy. In this study, five consumer sleep-tracking devices, research-grade actigraphy, and polysomnography were used simultaneously to monitor the overnight sleep of fifty-three young adults in the lab for one night. Biases and limits of agreement were assessed to determine how sleep stage estimates for each device and research-grade actigraphy differed from polysomnography-derived measures. Every device, except the Garmin Vivosmart, was able to estimate total sleep time comparably to research-grade actigraphy. All devices overestimated nights with shorter wake times and underestimated nights with longer wake times. For light sleep, absolute bias was low for the Fitbit Inspire and Fitbit Versa. The Withings Mat and Garmin Vivosmart overestimated shorter light sleep and underestimated longer light sleep. The Oura Ring underestimated light sleep of any duration. For deep sleep, bias was low for the Withings Mat and Garmin Vivosmart while other devices overestimated shorter and underestimated longer times. For REM sleep, bias was low for all devices. Taken together, these results suggest that proportional bias patterns in consumer sleep-tracking technologies are prevalent and could have important implications for their overall accuracy.


Asunto(s)
Actigrafía , Trastornos del Sueño-Vigilia , Adulto Joven , Humanos , Polisomnografía/métodos , Actigrafía/métodos , Reproducibilidad de los Resultados , Sueño , Fases del Sueño
15.
J Clin Sleep Med ; 20(4): 497-503, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-37950454

RESUMEN

STUDY OBJECTIVES: This study sought to examine the relationship between actigraphy and the Consensus Sleep Diary to contribute information on their concurrent validity in a sample of career firefighters. METHODS: Sixty firefighters were recruited from a large, urban fire department in the southwest United States that utilizes a fire-based emergency medical services system and a 5/6 shift schedule. A total of 329 differences were recorded during participants' 6-day between-shift recovery period. Data was collected utilizing the two most common forms of sleep analysis in an outpatient setting, wrist actigraphy (Actiwatch-2) and the Consensus Sleep Diary. Nine major sleep indices were computed: wake time after sleep onset, total sleep time, sleep onset latency, sleep offset, in-bed time, lights-off time, out-of-bed time, wake time, and sleep efficiency. RESULTS: Firefighters overestimated sleep efficiency and underestimated wake after sleep onset by values that were greater than the American Academy of Sleep Medicine a priori clinical significance thresholds. All indices showed very broad limits of agreement. For example, the 95% confidence interval for diary and actigraphic total sleep time estimates fell within a 4.7-hour range. CONCLUSIONS: Firefighters receiving recovery sleep between tours demonstrated significantly large disagreements between their daily self-reported sleep and measured actigraphic sleep. Sleep findings from actigraphic and Consensus Sleep Diary sleep assessments in this population should be interpreted cautiously until each method is compared against other reliable sleep analysis methods. Currently it is unclear if clinicians are using properly validated tools when diagnosing shift work disorder or other sleep disorders in firefighters. CITATION: Marmis R, McGoldrick-Ruth L, Kelly MR, Haynes PL. Comparing actigraphy and diary to measure daily and average sleep in firefighters: a Bland-Altman analysis. J Clin Sleep Med. 2024;20(4):497-503.


Asunto(s)
Actigrafía , Bomberos , Humanos , Actigrafía/métodos , Sueño , Polisomnografía , Autoinforme
16.
J Neurosci Nurs ; 56(1): 6-11, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37972989

RESUMEN

ABSTRACT: BACKGROUND: Patients admitted to the neuroscience intensive care unit often experience varying states of confusion and restlessness. The purpose of this study was to examine restlessness in acutely confused patients through use of familiar photographs. METHODS : This randomized prospective pilot study placed family photographs (photos) on the bedrail of confused patients during the night shift (8 pm to 4 am ) in a neuroscience intensive care unit. Wrist actigraphy was used to examine restlessness when patients were turned to face the photos versus when they were not facing the photos. RESULTS: The 20 patients enrolled provided 34 nights worth of data during which 32 640 actigraph readings were obtained. On the first night of study, the odds of wrist movement were higher when the patient was facing the photos compared with not (odds ratio, 1.51; 95% confidence interval, 1.42-1.61). During subsequent nights, the odds of wrist movement were lower when the patient was facing the photos compared with not (odds ratio, 0.82; 95% confidence interval, 0.75-0.90). CONCLUSION : Use of familiar photos does not change restlessness, agitation, or delirium on the first night of observation. However, the use of familiar photos may decrease restlessness on the subsequent nights. There are important subjective observations from researchers and family that suggest all subjects had a noticeable response when initially seeing the familiar photos.


Asunto(s)
Actigrafía , Agitación Psicomotora , Humanos , Estudios Prospectivos , Proyectos Piloto , Actigrafía/métodos , Ansiedad
17.
J Sleep Res ; 33(1): e13960, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37282765

RESUMEN

This study compared weekday and weekend actigraphy-measured and parent-reported sleep in relation to weight status among preschool-aged children. Participants were 3-6 years old preschoolers from the cross-sectional DAGIS-study with sleep data for ≥2 weekday and ≥2 weekend nights. Parents-reported sleep onset and wake-up times were gathered alongside 24 h hip-worn actigraphy. An unsupervised Hidden-Markov Model algorithm provided actigraphy-measured night time sleep without the guidance of reported sleep times. Waist-to-height ratio and age-and-sex-specific body mass index characterised weight status. Comparison of methods were assessed with consistency in quintile divisions and Spearman correlations. Associations between sleep and weight status were assessed with adjusted regression models. Participants included 638 children (49% girls) with a mean ± SD age of 4.76 ± 0.89. On weekdays, 98%-99% of actigraphy-measured and parent-reported sleep estimates were classified in the same or adjacent quintile and were strongly correlated (rs = 0.79-0.85, p < 0.001). On weekends, 84%-98% of actigraphy-measured and parent-reported sleep estimates were respectively classified and correlations were moderate to strong (rs = 0.62-0.86, p < 0.001). Compared with actigraphy-measured sleep, parent-reported sleep had consistently earlier onset, later wake-up, and greater duration. Earlier actigraphy-measured weekday sleep onset and midpoint were associated with a higher body mass index (respective ß-estimates: -0.63, p < 0.01 and -0.75, p < 0.01) and waist-to-height ratio (-0.004, p = 0.03 and -0.01, p = 0.02). Though the sleep estimation methods were consistent and correlated, actigraphy measures should be favoured as they are more objective and sensitive to identifying associations between sleep timing and weight status compared with parent reports.


Asunto(s)
Actigrafía , Sueño , Masculino , Femenino , Humanos , Preescolar , Niño , Actigrafía/métodos , Estudios Transversales , Índice de Masa Corporal , Algoritmos
18.
Nutr Clin Pract ; 39(2): 426-436, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37777983

RESUMEN

BACKGROUND: Patients receiving home parenteral nutrition (HPN) frequently report disrupted sleep. However, there are often inconsistencies between objectively measured and questionnaire-derived sleep measures. We compared sleep measures estimated from wrist actigraphy and self-report in adults receiving HPN. METHODS: In this secondary analysis, we pooled data from two sleep-related studies enrolling adults receiving habitual HPN. We compared measures from 7-day averages of wrist actigraphy against comparable responses to a sleep questionnaire. Sleep measures included bedtime, wake time, time in bed, total sleep time, and sleep onset latency (SOL). Spearman correlation coefficients, Bland-Altman plots, and linear regression models for each set of sleep measures provided estimates of agreement. RESULTS: Participants (N = 35) had a mean age of 52 years, body mass index of 21.6 kg/m2 , and 77% identified as female. Correlation coefficients ranged from 0.35 to 0.90, were highest for wake time (r = 0.90) and bedtime (r = 0.74), and lowest for total sleep time (r = 0.35). Actigraphy overestimated self-reported bedtime, wake time, and total sleep time and underestimated self-reported time in bed and SOL. Regression coefficients indicated the highest calibration for bedtime and wake time and lower calibration for time in bed, total sleep time, and SOL. CONCLUSION: We observed strong-to-moderate agreement between sleep measures derived from wrist actigraphy and self-report in adults receiving HPN. Weaker correlations for total sleep time and SOL may indicate low wrist actigraphy sensitivity. Low-quality sleep resulting from sleep disruptions may have also contributed to an underreporting of perceived sleep quantity and lower concordance.


Asunto(s)
Actigrafía , Sueño , Adulto , Femenino , Humanos , Persona de Mediana Edad , Actigrafía/métodos , Polisomnografía/métodos , Autoinforme , Sueño/fisiología , Encuestas y Cuestionarios , Masculino
19.
Behav Res Ther ; 173: 104464, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38159415

RESUMEN

Previous research has suggested that individuals with major depressive disorder (MDD) experienced alterations in sleep and activity levels. However, the temporal associations among sleep, activity levels, mood, and daytime symptoms in MDD have not been fully investigated. The present study aimed to fill this gap by utilizing real-time data collected across time points and days. 75 individuals with MDD and 75 age- and gender-matched healthy controls were recruited. Ecological momentary assessments (EMA) were adopted to assess real-time mood status for 7 days, and actigraphy was employed to measure day-to-day sleep-activity patterns. Multilevel modeling analyses were performed. Results revealed a bidirectional association between mood/daytime symptoms and activity levels across EMA intervals. Increased activity levels were predictive of higher alert cognition and positive mood, while an increase in positive mood also predicted more increase in activity levels in depressed individuals. A bidirectional association between sleep and daytime symptoms was also found. Alert cognition was found to be predictive of better sleep in the subsequent night. Contrariwise, higher sleep efficiency predicted improved alert cognition and sleepiness/fatigue the next day. A unidirectional association between sleep and activity levels suggested that higher daytime activity levels predicted a larger increase in sleep efficiency among depressed individuals. This study indicated how mood, activity levels, and sleep were temporally and intricately linked to each other in depressed individuals using actigraphy and EMA. It could pave the way for novel and efficacious treatments for depression that target not just mood but sleep and activity levels.


Asunto(s)
Trastorno Depresivo Mayor , Humanos , Actigrafía/métodos , Evaluación Ecológica Momentánea , Sueño , Afecto
20.
J Med Internet Res ; 25: e51336, 2023 12 13.
Artículo en Inglés | MEDLINE | ID: mdl-38090797

RESUMEN

BACKGROUND: Sleep disturbances are core symptoms of psychiatric disorders. Although various sleep measures have been developed to assess sleep patterns and quality of sleep, the concordance of these measures in patients with psychiatric disorders remains relatively elusive. OBJECTIVE: This study aims to examine the degree of agreement among 3 sleep recording methods and the consistency between subjective and objective sleep measures, with a specific focus on recently developed devices in a population of individuals with psychiatric disorders. METHODS: We analyzed 62 participants for this cross-sectional study, all having data for polysomnography (PSG), Zmachine, Fitbit, and sleep logs. Participants completed questionnaires on their symptoms and estimated sleep duration the morning after the overnight sleep assessment. The interclass correlation coefficients (ICCs) were calculated to evaluate the consistency between sleep parameters obtained from each instrument. Additionally, Bland-Altman plots were used to visually show differences and limits of agreement for sleep parameters measured by PSG, Zmachine, Fitbit, and sleep logs. RESULTS: The findings indicated a moderate agreement between PSG and Zmachine data for total sleep time (ICC=0.46; P<.001), wake after sleep onset (ICC=0.39; P=.002), and sleep efficiency (ICC=0.40; P=.006). In contrast, Fitbit demonstrated notable disagreement with PSG (total sleep time: ICC=0.08; wake after sleep onset: ICC=0.18; sleep efficiency: ICC=0.10) and exhibited particularly large discrepancies from the sleep logs (total sleep time: ICC=-0.01; wake after sleep onset: ICC=0.05; sleep efficiency: ICC=-0.02). Furthermore, subjective and objective concordance among PSG, Zmachine, and sleep logs appeared to be influenced by the severity of the depressive symptoms and obstructive sleep apnea, while these associations were not observed between the Fitbit and other sleep instruments. CONCLUSIONS: Our study results suggest that Fitbit accuracy is reduced in the presence of comorbid clinical symptoms. Although user-friendly, Fitbit has limitations that should be considered when assessing sleep in patients with psychiatric disorders.


Asunto(s)
Trastornos del Sueño-Vigilia , Sueño , Humanos , Polisomnografía/métodos , Estudios Transversales , Reproducibilidad de los Resultados , Trastornos del Sueño-Vigilia/diagnóstico , Electroencefalografía , Actigrafía/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...